AC Protection Box Enphase Three-phase GAVE ACT-E1C 20A 30mA
Modelo: ACT-E1C- Sku: GAVEPRO012
- Vendor: GAVE
Specifications
Product description
The Enphase Three-Phase AC Protection Box GAVE ACT-E1C 20A 30mA is a 3F+N connection and safety panel that integrates, in a single Class II enclosure, all the key functions of a three-phase Enphase IQ system: isolation, circuit breaker and residual current protection, overvoltage protection, and the environment for three-phase Q-Relay, IQ Gateway/Envoy (metered), and current transformers (CT) for production and consumption. Designed to streamline installation and ensure regulatory compliance, it offers a professional and robust finish (IK08) suitable for demanding locations.
Main features
- 3F+N configuration for 1 AC circuit with capacity up to 20 A per phase (≈ 13.9 kVA at 3×400/230 V).
- 4P 20 A circuit breaker, curve C, 6 kA (EN 60898-1) for protection against short circuits and overloads.
- 4P Type A 30 mA residual current device with immunity to unwanted tripping, compatible with electronic loads.
- Type II SPD overvoltage protection (In 20 kA, Imax 40 kA, Up 1.5 kV) for grid interface protection.
- Plug & play preparation for the Enphase ecosystem: Q-Relay 3F, IQ Gateway/Envoy (Metered), and split-core CT.
- Polycarbonate enclosure, double insulation Class II, IK08 resistance, and field-ready design.
Advantages or benefits
- Saves time and reduces errors by concentrating protections, measurement, and communications in a single panel.
- Maximum safety with 30 mA RCD and Type II SPD that reduce risks from indirect contact and overvoltages.
- Ready for advanced monitoring, power control, and export limitation via Envoy (metered).
- Facilitates compliance with distributor requirements thanks to the three-phase Q-Relay disconnection.
- Clean and maintainable installation: streamlined wiring, accessible terminals, and clear labeling.
Purpose or applications
Oriented towards residential and small commercial (C&I) three-phase self-consumption with Enphase HMT/MIT microinverters or Enphase three-phase strings in Europe, both in installations with grid export and those requiring export limitation. Also suitable for setups with AC-coupled batteries (e.g., Enphase IQ Battery 5P) where the panel acts as the central point for protection and measurement on the AC side.
Technical specifications
| Power | Up to ≈ 13.9 kVA (20 A/phase at 3×400/230 V) |
| Rated voltage | 3×400/230 V~ · 50 Hz (three-phase 3F+N) |
| Format | Modular polycarbonate enclosure, Class II, IK08 |
| Magnetothermal protection | 4P 20 A · curve C · 6 kA (EN 60898-1) |
| Residual current protection | Type A · 30 mA · 4P · immunized (EN 61008-1) |
| SPD | Type II · In 20 kA · Imax 40 kA · Up 1.5 kV |
| Circuits | 1 three-phase AC PV circuit |
| Dimensions | Approx. 586 × 418 × 148 mm (height × width × depth) |
Compatibilities
Compatible with the Enphase IQ three-phase ecosystem (EU/INT): HMT/MIT microinverters, IQ Gateway/Envoy with metering, Q-Relay 3F, and production/consumption CTs. Integrable in systems with Enphase IQ Battery 5P in three-phase AC coupling.
Enphase AC Protection Box Three-phase GAVE ACT-E1C 20A 30mA is the professional option for centralizing protection, measurement, and control in Enphase 3F+N installations, improving safety, organization, and efficiency from day one.