Three-phase AC Protection Box GAVE ACT10SDA 7kW 10A 30mA
Modelo: ACT10SDA- Sku: GAVEPRO005
- Vendor: GAVE
Specifications
Product description
The GAVE ACT10SDA 7kW 10A 30mA Three-Phase AC Protection Box brings together in a single 3F+N enclosure everything needed to connect and protect a three-phase AC branch of up to ~7 kW. It incorporates a four-pole circuit breaker, high-sensitivity Type A residual current device, and Type II surge protection device (SPD), providing electrical safety, organized wiring, and fast, professional installation in residential or small tertiary applications.
Main features
- Three-phase panel 3F+N for 1 circuit with capacity up to 10 A per phase (≈ 6.9–7 kVA at 3×400 V).
- 4P 10 A circuit breaker, curve C, breaking capacity 6 kA in accordance with EN 60898-1.
- Type A residual current device 30 mA (immune to unwanted tripping) according to EN 61008-1.
- Overvoltage protection SPD Type II (In 20 kA, Imax 40 kA, Up 1.5 kV) according to EN 61643-11.
- Polycarbonate enclosure, double insulation Class II, high mechanical resistance, suitable for protected outdoor use.
Advantages or benefits
- Faster and cleaner installation: centralizes disconnection, protections, and interconnection point.
- Enhanced safety for people and equipment with 30 mA RCD and Type II SPD in the same panel.
- Facilitated technical compliance and streamlined wiring for easy maintenance.
- Compact format with DIN rail and accessible terminals that optimize the available space.
Purpose or applications
Ideal as a protection panel for residential or small tertiary three-phase self-consumption, branches of three-phase microinverters or low-power string inverters (~5–7 kW), and AC-coupled battery systems when the line current does not exceed 10 A per phase.
Technical specifications
| Power | ≈ 7 kW (10 A/phase at 3×400 V) |
| Nominal voltage | 3×400/230 V~ · 50 Hz (3P+N) |
| Format | Polycarbonate · Class II (double insulation) · DIN rail |
| Magnetothermal protection | 4P 10 A · curve C · 6 kA (EN 60898-1) |
| Residual current protection | Type A · 30 mA · 4 poles (EN 61008-1) |
| SPD | Type II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11) |
| Dimensions | ≈ 286 × 418 × 148 mm (height × width × depth) |
| Circuits | 1 dedicated three-phase AC circuit |
Compatibilities
Compatible with three-phase microinverters (e.g., HMT/MIT branches or other ecosystems) and with three-phase string inverters of ~5–7 kW, provided the aggregate does not exceed 10 A per phase. Integrable with monitoring systems via external CT/meters and can be coordinated with main circuit breaker, general residual current device, and main SPD according to the project.
GAVE ACT10SDA 7kW 10A 30mA Three-Phase AC Protection Box is the professional option to centralize safety, order, and reliability in the AC interface of your installation, optimizing assembly times and protecting equipment and people from day one.
Have a question?

Three-phase AC Protection Box GAVE ACT10SDA 7kW 10A 30mA