Three-phase AC Protection Box GAVE ACT16SDA 11kW 16A 30mA
Modelo: ACT16SDA- Sku: GAVEPRO006
- Vendor: GAVE
Specifications
Product description
The GAVE ACT16SDA 11kW 16A 30mA Three-Phase AC Protection Box brings together in a single 3F+N enclosure all critical safety functions for an AC branch of up to ~11 kW: isolation, circuit breaker protection, high-sensitivity residual current protection, and overvoltage limitation (Type II SPD). Its modular design with double insulation (Class II) in polycarbonate enables quick, tidy installation in accordance with best practices, reducing installation time and future interventions.
Main features
- Three-phase 3F+N configuration for 1 AC circuit with capacity up to 16 A/phase (≈ 11 kVA/kW at 3×400 V).
- Miniature circuit breaker (MCB) 4P 16 A, curve C, breaking capacity 6 kA (EN 60898-1).
- Residual current device (RCD) Type A 30 mA, 4 poles, immune to unwanted tripping (EN 61008-1).
- Overvoltage protection SPD Type II (In 20 kA, Imax 40 kA, Up 1.5 kV) in accordance with EN 61643-11.
- Polycarbonate enclosure with double insulation Class II, high mechanical strength, and DIN rail.
- Compact dimensions (≈ 286 × 418 × 148 mm) that facilitate integration into the technical room.
Advantages or benefits
- Agile installation: turnkey panel that centralizes protections, isolation, and interconnection point.
- Enhanced safety: 30 mA RCD protects people and Type II SPD mitigates grid transients.
- Clean and maintainable installation: streamlined wiring, accessible terminals, and clear labeling.
- Facilitates technical compliance and selectivity with upstream protections from the main distribution board.
- Versatility: suitable for 3-phase string inverters ~8–12 kW or branches of three-phase microinverters (≤ 16 A/phase).
Purpose or applications
Recommended for residential and small tertiary three-phase self-consumption, as well as for AC-coupled battery schemes when the line current does not exceed 16 A/phase. Functions as a safe and professional interconnection point between the AC generator/backup and the main distribution board, with or without export limitation depending on the monitoring system configuration.
Technical specifications
| Power | ≈ 11 kW (16 A/phase at 3×400 V) |
| Rated voltage | 3×400/230 V~ · 50 Hz (3F+N) |
| Format | Modular polycarbonate enclosure · Class II (double insulation) · DIN rail |
| Magnetothermal protection | 4P 16 A · curve C · 6 kA (EN 60898-1) |
| Residual current protection | Type A · 30 mA · 4 poles · immunized (EN 61008-1) |
| SPD | Type II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11) |
| Circuits | 1 dedicated three-phase AC circuit |
| Dimensions | ≈ 286 × 418 × 148 mm (height × width × depth) |
Compatibilities
Compatible with three-phase inverters of ~8–12 kW and with 3F microinverter branches (Enphase HMT/MIT or others), provided the total does not exceed 16 A/phase. Can be coordinated with main circuit breaker, general residual current device, and main SPD according to the project, and can be integrated with monitoring via current transformers or external meters.
GAVE ACT16SDA 11kW 16A 30mA Three-Phase AC Protection Box is the professional option to centralize safety, order, and reliability in the AC interface of your installation, optimizing assembly times and protecting equipment and people from day one.
Have a question?

Three-phase AC Protection Box GAVE ACT16SDA 11kW 16A 30mA