Skip to product information
Sale

Three-Phase AC Protection Box GAVE ACT32SDA 22kW 32A 30mA

Modelo: ACT32SDA
  • Sku: GAVEPRO008
  • Vendor: GAVE
€377,19 EUR
€301,76 EUR
 per 
Tax included.
Shipping calculated at checkout.
In stock!
Spend €150,00 to FREE SHIPPING

GAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box combines disconnection and 3P+N safety in a single panel. Incorporates 4P MCB and RCD of 32 A / 30 mA and Type II SPD in a robust Class II enclosure.

Purchase with Secure Payment

Specifications

Product Description

The GAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box is a turnkey 3F+N panel that centralizes protections, disconnection, and the interconnection point of the AC branch in installations up to ~22 kW. It integrates a four-pole miniature circuit breaker, high-sensitivity residual current device, and surge protection device (SPD Type II) in a polycarbonate enclosure with double insulation (Class II), offering quick, organized installation in accordance with best practices.

Main Features

  • Three-phase 3F+N capacity for 1 AC circuit: up to 32 A/phase (≈ 22.1 kVA/kW at 3×400/230 V).
  • Miniature circuit breaker (MCB) 4P 32 A, curve C, breaking capacity 6 kA (EN 60898-1).
  • Residual current device (RCD) 4P Type A 30 mA, immune to unwanted tripping (EN 61008-1).
  • Surge protection SPD Type II – PSTC440: In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11).
  • Polycarbonate enclosure Class II (double insulation), high mechanical strength, DIN rail, and streamlined wiring.

Advantages or Benefits

  • Fast and clean installation by concentrating all AC-side protections in a single panel.
  • Enhanced safety for people (RCD 30 mA) and equipment (Type II SPD against transients).
  • Facilitates technical compliance and selectivity with upstream protections.
  • Simple maintenance: front access to devices, accessible terminals, and clear labeling.

Purpose or Applications

Ideal for residential/tertiary three-phase self-consumption and light C&I with string inverters of ~15–22 kW or 3F microinverter branches, as well as for systems with AC-coupled batteries when the line current does not exceed 32 A per phase.

Technical Specifications

Power ≈ 22.1 kW (32 A/phase at 3×400 V)
Nominal voltage 3×400/230 V~ · 50 Hz (3F+N)
Format Polycarbonate · Class II (double insulation) · DIN rail
Miniature circuit breaker protection 4P 32 A · curve C · 6 kA (EN 60898-1)
Residual current protection Type A · 30 mA · 4 poles · immune (EN 61008-1)
SPD Type II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11)
Circuits 1 dedicated three-phase AC circuit
Dimensions ≈ 286 × 418 × 148 mm (height × width × depth)

Compatibilities

Compatible with three-phase inverters of ~15–22 kW and with 3F microinverter branches (provided the total does not exceed 32 A/phase). Can be coordinated with main circuit breaker, general RCD, and main SPD as per project; can be integrated with monitoring via CT or external meters.

GAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box is the professional option to centralize safety, organization, and reliability at the AC interface of your installation, optimizing installation time and protecting equipment and people from day one.

PDF Icon Descargar ficha técnica View full details

Three-Phase AC Protection Box GAVE ACT32SDA 22kW 32A 30mA

€377,19 EUR
€301,76 EUR
 per 

Recently viewed