Three-Phase AC Protection Box GAVE ACT32SDA 22kW 32A 30mA
Modelo: ACT32SDA- Sku: GAVEPRO008
- Vendor: GAVE
Specifications
Product Description
The GAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box is a turnkey 3F+N panel that centralizes protections, disconnection, and the interconnection point of the AC branch in installations up to ~22 kW. It integrates a four-pole miniature circuit breaker, high-sensitivity residual current device, and surge protection device (SPD Type II) in a polycarbonate enclosure with double insulation (Class II), offering quick, organized installation in accordance with best practices.
Main Features
- Three-phase 3F+N capacity for 1 AC circuit: up to 32 A/phase (≈ 22.1 kVA/kW at 3×400/230 V).
- Miniature circuit breaker (MCB) 4P 32 A, curve C, breaking capacity 6 kA (EN 60898-1).
- Residual current device (RCD) 4P Type A 30 mA, immune to unwanted tripping (EN 61008-1).
- Surge protection SPD Type II – PSTC440: In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11).
- Polycarbonate enclosure Class II (double insulation), high mechanical strength, DIN rail, and streamlined wiring.
Advantages or Benefits
- Fast and clean installation by concentrating all AC-side protections in a single panel.
- Enhanced safety for people (RCD 30 mA) and equipment (Type II SPD against transients).
- Facilitates technical compliance and selectivity with upstream protections.
- Simple maintenance: front access to devices, accessible terminals, and clear labeling.
Purpose or Applications
Ideal for residential/tertiary three-phase self-consumption and light C&I with string inverters of ~15–22 kW or 3F microinverter branches, as well as for systems with AC-coupled batteries when the line current does not exceed 32 A per phase.
Technical Specifications
| Power | ≈ 22.1 kW (32 A/phase at 3×400 V) |
| Nominal voltage | 3×400/230 V~ · 50 Hz (3F+N) |
| Format | Polycarbonate · Class II (double insulation) · DIN rail |
| Miniature circuit breaker protection | 4P 32 A · curve C · 6 kA (EN 60898-1) |
| Residual current protection | Type A · 30 mA · 4 poles · immune (EN 61008-1) |
| SPD | Type II · In 20 kA · Imax 40 kA · Up 1.5 kV (EN 61643-11) |
| Circuits | 1 dedicated three-phase AC circuit |
| Dimensions | ≈ 286 × 418 × 148 mm (height × width × depth) |
Compatibilities
Compatible with three-phase inverters of ~15–22 kW and with 3F microinverter branches (provided the total does not exceed 32 A/phase). Can be coordinated with main circuit breaker, general RCD, and main SPD as per project; can be integrated with monitoring via CT or external meters.
GAVE ACT32SDA 22kW 32A 30mA Three-Phase AC Protection Box is the professional option to centralize safety, organization, and reliability at the AC interface of your installation, optimizing installation time and protecting equipment and people from day one.
Have a question?

Three-Phase AC Protection Box GAVE ACT32SDA 22kW 32A 30mA